7 to 18 Horsepower Air
Cooled Scroll Capacity Tables
Drake
Compressor
LWT
80
90
95
100
105
Model
ºF
TONS
KW
EER
TONS
KW
EER
TONS
KW
EER
TONS
KW
EER
TONS
KW
EER
70S
ZB56K
42.0
6.3
5.7
10.5
6.0
6.3
9.3
5.9
6.7
8.7
5.8
7.0
8.1
5.6
7.4
7.6
44.0
6.5
5.7
10.8
6.2
6.3
9.6
6.1
6.7
9.0
5.9
7.0
8.4
5.8
7.4
7.8
45.0
6.6
5.7
11.0
6.4
6.4
9.7
6.2
6.7
9.1
6.1
7.1
8.5
5.9
7.4
8.0
50.0
7.1
5.8
11.7
6.8
6.4
10.4
6.7
6.8
9.7
6.5
7.1
9.1
6.4
7.5
8.5
55.0
7.7
5.9
12.6
7.4
6.5
11.1
7.2
6.9
10.4
7.0
7.2
9.7
6.9
7.6
9.1
60.0
8.3
6.0
13.3
7.9
6.6
11.7
7.7
7.0
11.0
7.5
7.3
10.3
7.3
7.7
9.6
80S
ZB68K
42.0
7.7
7.0
10.8
7.3
7.8
9.4
6.9
8.2
8.8
6.9
8.7
8.2
6.8
9.1
7.7
44.0
7.9
7.1
11.1
7.5
7.8
9.7
7.2
8.3
9.1
7.2
8.7
8.5
7.0
9.2
7.9
45.0
8.0
7.1
11.3
7.7
7.9
9.9
7.3
8.3
9.2
7.3
8.7
8.6
7.1
9.2
8.0
50.0
8.7
7.2
12.0
8.3
8.0
10.5
7.9
8.4
9.8
7.9
8.8
9.2
7.7
9.3
8.5
55.0
9.3
7.3
12.8
8.9
8.0
11.2
8.5
8.5
10.5
8.5
8.9
9.8
8.3
9.4
9.1
60.0
10.0
7.4
13.6
9.5
8.1
11.9
9.0
8.6
11.1
9.0
9.0
10.3
8.8
9.5
9.6
90S
ZB75K
42.0
8.8
8.3
10.8
8.3
9.2
9.4
8.2
9.7
8.8
7.9
10.2
8.2
7.8
10.7
7.6
44.0
9.0
8.3
11.1
8.6
9.2
9.7
8.4
9.7
9.0
8.2
10.2
8.4
8.0
10.7
7.8
45.0
9.2
8.3
11.2
8.8
9.2
9.8
8.5
9.7
9.1
8.3
10.2
8.5
8.1
10.8
7.9
50.0
9.9
8.5
11.9
9.4
9.4
10.2
9.2
9.9
9.7
8.9
10.4
9.1
8.7
10.9
8.5
55.0
10.7
8.6
12.7
10.2
9.5
11.1
9.9
10.0
10.4
9.7
10.5
9.7
9.4
11.1
9.0
60.0
11.4
8.7
13.5
10.8
9.6
11.7
10.5
10.1
10.9
10.3
10.6
10.2
10.0
11.2
9.5
120S
ZB92K
42.0
10.8
10.3
11.0
10.3
11.3
9.6
10.0
11.9
9.0
9.8
12.5
8.4
9.5
13.1
7.9
44.0
11.1
10.4
11.3
10.6
11.4
9.9
10.3
12.0
9.3
10.1
12.5
8.6
9.8
13.1
8.1
45.0
11.3
10.4
11.4
10.8
11.4
10.0
10.5
12.0
9.4
10.2
12.6
8.8
10.0
13.2
8.2
50.0
12.2
10.6
12.1
11.7
11.6
10.7
11.3
12.2
10.0
11.1
12.8
9.3
10.8
13.4
8.7
55.0
13.1
10.8
12.8
12.5
11.8
11.3
12.2
12.4
10.6
11.9
13.0
9.9
11.6
13.6
9.2
60.0
14.0
11.0
13.5
13.3
12.0
11.9
13.0
12.6
11.1
12.7
13.2
10.4
12.3
13.8
9.7
180S
ZB11M
42.0
13.3
12.2
10.2
12.7
13.5
9.0
12.4
14.2
8.4
12.1
14.9
7.9
11.8
15.7
7.4
44.0
13.7
12.2
10.5
13.0
13.5
9.2
12.8
14.2
8.6
12.4
15.0
8.1
12.1
15.8
7.5
45.0
13.9
12.2
10.6
13.3
13.5
9.4
12.9
14.3
8.8
12.6
15.0
8.2
12.3
15.8
7.7
50.0
14.8
12.3
11.3
14.1
13.6
9.9
13.8
14.4
9.3
13.4
15.1
8.7
13.1
15.9
8.1
55.0
15.9
12.4
12.0
15.1
13.8
10.6
14.8
14.5
9.9
14.4
15.2
9.2
14.0
16.1
8.6
60.0
16.9
12.5
12.7
16.1
13.9
11.2
15.8
14.6
10.5
15.3
15.4
9.8
15.0
16.2
9.2
1. Capacities on this chart are based on refrigerant 22. Low
ambient or lower leaving water temperatures can require the use of a glycol
solution or other fluid blends. These solutions affect unit capacities.
Please consult the factory on these or other special fluids.
2. kW input is for compressor(s) only.
3. EER = Energy Efficiency Ratio (BTU/watt-hour). Power
inputs include compressor(s), condenser fan motor(s) and control power